Schneider Electric RE22 Series DIN Rail Timer Relay, 1-Contact, 24 to 240 V dc 24V ac, 240 V ac, 0.05 s to 10 min,
- RS Stock No.:
- 896-8695
- Distrelec Article No.:
- 303-02-782
- Mfr. Part No.:
- RE22R1KMR
- Manufacturer:
- Schneider Electric
Bulk discount available
Subtotal (1 unit)*
TWD3,110.00
(exc. GST)
TWD3,265.50
(inc. GST)
FREE delivery for orders over NT$1,300.00
In Stock
- Plus 15 unit(s) shipping from May 25, 2026
- Plus 8 unit(s) shipping from June 19, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 4 | TWD3,110.00 |
| 5 - 9 | TWD3,048.00 |
| 10 + | TWD2,987.00 |
*price indicative
- RS Stock No.:
- 896-8695
- Distrelec Article No.:
- 303-02-782
- Mfr. Part No.:
- RE22R1KMR
- Manufacturer:
- Schneider Electric
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Timer Relay | |
| Mount Type | DIN Rail | |
| Function | Offset Double Ring End | |
| Time Range | 0.05 s to 10 min | |
| Number of Contacts | 1 | |
| Switching Voltage | 250V ac | |
| Number of Timer Functions | 1 | |
| Contact Configuration | 1 CO | |
| IP Rating | IP20, IP40, IP50 | |
| Supply DC Voltage | 24 to 240 V dc | |
| Contact Current | 5A | |
| Minimum Operating Temperature | -20°C | |
| Timing Adjustment | Knob | |
| Supply AC Voltage | 24, 240V ac | |
| Maximum Operating Temperature | 60°C | |
| Terminal Type | Screw | |
| Standards/Approvals | CCC, CSA, GL, UL 508, RCM, CE, EAC, IEC 61812-1, UL | |
| Height | 79.5mm | |
| Length | 22.9mm | |
| Width | 22.5mm | |
| Series | RE22 | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Timer Relay | ||
Mount Type DIN Rail | ||
Function Offset Double Ring End | ||
Time Range 0.05 s to 10 min | ||
Number of Contacts 1 | ||
Switching Voltage 250V ac | ||
Number of Timer Functions 1 | ||
Contact Configuration 1 CO | ||
IP Rating IP20, IP40, IP50 | ||
Supply DC Voltage 24 to 240 V dc | ||
Contact Current 5A | ||
Minimum Operating Temperature -20°C | ||
Timing Adjustment Knob | ||
Supply AC Voltage 24, 240V ac | ||
Maximum Operating Temperature 60°C | ||
Terminal Type Screw | ||
Standards/Approvals CCC, CSA, GL, UL 508, RCM, CE, EAC, IEC 61812-1, UL | ||
Height 79.5mm | ||
Length 22.9mm | ||
Width 22.5mm | ||
Series RE22 | ||
- COO (Country of Origin):
- ID
Schneider Electric RE22 Series Timer Relay, 0.05s–10min Time Range, 5A Contact Current - RE22R1KMR
This timer relay provides timed switching for control panels and automation systems, operating from low-voltage to high-voltage supply environments. It is intended for DIN-rail mounting in electrical cabinets and performs a specialised offset double-ring end timing function to manage sequence control in industrial installations.
Features & Benefits
• Single changeover contact rated for 5A protects downstream circuits
• Configurable time span from 0.05 s to 10 min suits varied cycle requirements
• Supply range 24 to 240V AC/DC enables versatile power connections
• Screw terminals simplify secure wiring for permanent installations
• Knob adjustment offers Rapid on-site timing fine-tuning
• Switching capability up to 250V AC supports mains-level loads
• Configurable time span from 0.05 s to 10 min suits varied cycle requirements
• Supply range 24 to 240V AC/DC enables versatile power connections
• Screw terminals simplify secure wiring for permanent installations
• Knob adjustment offers Rapid on-site timing fine-tuning
• Switching capability up to 250V AC supports mains-level loads
Applications
• Suitable for conveyor sequencing where adjustable intervals are needed
• Ideal for pump control with precise delayed stop or start actions
• used with motor starters to insert timed interlocks in control loops
• Can be used for lighting circuits requiring timed shutdowns
• Used for process automation that demands single-contact timing events
• Ideal for pump control with precise delayed stop or start actions
• used with motor starters to insert timed interlocks in control loops
• Can be used for lighting circuits requiring timed shutdowns
• Used for process automation that demands single-contact timing events
What mounting method is required for installation?
It clips onto a standard DIN rail for quick integration into control panels.
Which environmental temperatures can it tolerate during operation?
It is rated for continuous use between −20 °C and 60 °C in typical industrial settings.
How many timer functions are available and how are they selected?
There is a single timing function provided
selection is MADE by setting the front knob to the required interval.
What ingress protection options are provided for different panel conditions?
Variants are specified with IP20, IP40 or IP50 ratings to match differing dust and access protection needs.
What is the physical contact arrangement and how does it affect wiring?
It offers one changeover contact (1 CO), allowing a single switching circuit to be controlled with common, normally open and normally closed connections.
Related links
- Schneider Electric RE22 Series DIN Rail Timer Relay 240 V dc 24V ac 0.05 s to 300 h
- Schneider Electric Harmony Time Series DIN Rail Timer Relay 24 to 240 V ac/dc 24V ac 0.05 to 300
- Schneider Electric Harmony Time Series DIN Rail Timer Relay 24 V dc 24V ac 0.05 to 300 s,
- ENTES Miniature Circuit Breaker Series DIN Rail Timer Relay 240 V dc 24V ac 0.05 to 100 h,
- ABB CT-C Series DIN Rail Timer Relay 24 to 240 V dc 24V ac 0.05 s to 100 h,
- Siemens 3RP25 Series DIN Rail Timer Relay 12 to 240 V dc 24V ac 0.05 s to 100 h SPDT
- Tele E1ZM10 Series DIN Rail Timer Relay 240 V dc 24V ac 0.05 s to 100 h
- Finder 80 Series DIN Rail Timer Relay 240 V dc 24V ac 0.05 to 180 s SPDT Switch