Fluke 179 Handheld Digital Multimeter True RMS, 10 A, 10 A, 1 kV
- RS Stock No.:
- 394-4492
- Distrelec Article No.:
- 176-05-843
- Mfr. Part No.:
- FLUKE 179
- Manufacturer:
- Fluke
The image is for reference only, please refer to product details and specifications
Subtotal (1 unit)*
TWD22,491.00
(exc. GST)
TWD23,615.55
(inc. GST)
FREE delivery for orders over NT$1,300.00
- 175 unit(s) ready to ship from another location
- Plus 1 unit(s) shipping from November 23, 2026
- Plus 2 unit(s) shipping from December 07, 2026
Units | Per unit |
|---|---|
| 1 - 4 | TWD22,491.00 |
| 5 + | TWD21,814.00 |
*price indicative
- RS Stock No.:
- 394-4492
- Distrelec Article No.:
- 176-05-843
- Mfr. Part No.:
- FLUKE 179
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Digital Multimeter | |
| Multimeter Type | Handheld | |
| Resistance Resolution | 100mΩ | |
| Display Type | LCD | |
| Model Number | 179 | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature | |
| Maximum Resistance Measurement | 0.05GΩ | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum AC Current Measurement | 10A | |
| Maximum DC Current Measurement | 10A | |
| Maximum AC Voltage Measurement | 1kV | |
| True RMS | Yes | |
| AC Current Accuracy | ±1.5 % rdg + 3 Digits | |
| DC Voltage Accuracy | ± 0.09 % + 2 | |
| DC Current Accuracy | ±1 % rdg + 3 Digits | |
| AC Voltage Accuracy | ±1 % rdg + 3 Digits | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Voltage Resolution | 0.1 mV dc | |
| DC Current Resolution | 0.01mA dc | |
| AC Current Resolution | 10μA ac | |
| Maximum Frequency | 1kHz | |
| Power Source | Battery | |
| Resistance Measurement Accuracy | 0.9% + 1 | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 200h | |
| Standards/Approvals | No | |
| Weight | 420g | |
| Width | 90mm | |
| Length | 185mm | |
| Height | 43mm | |
| Safety Category Level | CAT III, CAT IV | |
| Battery Type | Alkaline | |
| Safety Category Voltage | 1kV | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Digital Multimeter | ||
Multimeter Type Handheld | ||
Resistance Resolution 100mΩ | ||
Display Type LCD | ||
Model Number 179 | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature | ||
Maximum Resistance Measurement 0.05GΩ | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum AC Current Measurement 10A | ||
Maximum DC Current Measurement 10A | ||
Maximum AC Voltage Measurement 1kV | ||
True RMS Yes | ||
AC Current Accuracy ±1.5 % rdg + 3 Digits | ||
DC Voltage Accuracy ± 0.09 % + 2 | ||
DC Current Accuracy ±1 % rdg + 3 Digits | ||
AC Voltage Accuracy ±1 % rdg + 3 Digits | ||
AC Voltage Resolution 0.1mV ac | ||
DC Voltage Resolution 0.1 mV dc | ||
DC Current Resolution 0.01mA dc | ||
AC Current Resolution 10μA ac | ||
Maximum Frequency 1kHz | ||
Power Source Battery | ||
Resistance Measurement Accuracy 0.9% + 1 | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Battery Life 200h | ||
Standards/Approvals No | ||
Weight 420g | ||
Width 90mm | ||
Length 185mm | ||
Height 43mm | ||
Safety Category Level CAT III, CAT IV | ||
Battery Type Alkaline | ||
Safety Category Voltage 1kV | ||
RoHS Status: Exempt
- COO (Country of Origin):
- US
Fluke Digital Multimeter, 1000V Safety Category Voltage, 10A Maximum DC Current Measurement - FLUKE 179
Features and Benefits:
• DC voltage accuracy of 0.09% rdg for precision diagnostics
• Maximum current handling of 10A facilitating load testing
• Resistance span to 0.05GΩ enabling high-value component checks
• 0.01mA current resolution for fine current measurements
• 200h battery life for extended field operation
Applications
• Ideal for electricians measuring up to 1000V in distribution systems
• Used for component testing involving capacitance and diode checks
• Can be used for HVAC verification using temperature and frequency functions
• Used with control panels for resistance measurements up to 0.05GΩ
What input protection level does it support for high-voltage systems?
How does it handle alternating quantity measurements?
What frequency range can be measured for signal analysis?
Which resistance and continuity capabilities are available for circuit diagnostics?
What environmental limits affect its operation during on-site use?
Contents
80BK Temperature Probe
Installed 9V battery
Test leads
Quick Reference Guide
Related links
- RS PRO Black 3 mm² Hook Up Wire 30m
- RS PRO RS-172 Temperature & Humidity Data Logger
- 2961105 | Phoenix Contact PCB Mount Power Relay 6A Switching Current, SPDT
- Tedea Huntleigh Low Profile Load Cell Compression Measure
- ABB D45 Pluto Series Safety Controller 6 Safety Outputs, 24 V dc
- TE Connectivity Coaxial Cable RG400 Coaxial, Unterminated
- RS PRO I/O Extension Module for Use with RS PRO Logic Modules Digital
- Fluke 289 Handheld Digital Multimeter 10A ac Max 1000V ac Max