    Tele Frequency, Voltage Mains and System Protection, 3 Phase, DIN Rail

    Tele
    RS Stock No.:
    266-4272
    Mfr. Part No.:
    NA003-M64
    Manufacturer:
    Tele
    View all Monitoring Relays
    79 In stock for delivery within 6 working days
    Add to Basket
    units

    Added

    Price (VAT excluded) Each

    TWD17,190.00

    (exc. GST)

    TWD18,049.50

    (inc. GST)

    unitsPer unit
    1 +TWD17,190.00
    RS Stock No.:
    266-4272
    Mfr. Part No.:
    NA003-M64
    Manufacturer:
    Tele

    Product overview and Technical data sheets


    Legislation and Compliance

    RoHS Status: Not Applicable

    COO (Country of Origin):
    AT

    Product Details

    TELE Grid & System Protection Relay, Frequency & Volatage Monitoring for Alternative Power Generation


    One grid & system protection for worldwide use and all standards in one device. When operating alternative power generation, grid and system protection is required by law and disconnects the power generation system (photovoltaics, generator, battery buffer) from the grid in the event of a power failure. This ensures the safety of the distribution network, machines and people

    In case of a pre-defined state of grid failure the grid and system protection separates the energy generator (photovoltaics, generator, battery buffer) from the grid. Its function is very important for the reliable protection of the power grid and generating plants because it ensures that the connection of an energy generator does not impair the function or safety of the distribution grid.

    Features and Benefits


    TELE’s grid & system protection NA003-M64 consists of two components:
    Protection relay that measures the grid voltage and grid frequency. It also contains the actual protection functions and generates the signal for grid disconnection.
    1-2 tie switches that ensure the actual disconnection from the mains.

    For high availability of the supply network, short-term grid disturbances must not separate the generators from the grid. This function, called Fault Ride Through (FRT), refers in particular to short-term undervoltages and overvoltages. Depending on the type and power of the energy generator, different requirements apply, those can be adjusted via the parameterisation of the NA003-M64.

    One device for local & international markets
    Easy handling for service personnel and commissioning engineers
    Pre-configured parameter sets for different countries in Europe & worldwide
    Individual solutions can be implemented through a variety of configuration options
    Integrated FRT (Fault ride through)
    Replaces older devices without changes in the control cabinet due to design and availability of older certificates.

    Standards Include


    OVE TOR R25 NS SYNC; OVE TOR R25 NS ASYNC; OVE TOR R25 MS SYNC; OVE TOR R25 MS ASYNC; OOE TOR R25 NS SYNC; OOE TOR R25 NS ASYNC; OOE TOR R25 MS SYNC; OOE TOR R25 MS ASYNC; W TOR R25 NS SYNC; W TOR R25 NS ASYNC; W TOR R25 MS SYNC; W TOR R25 MS ASYNC; TIROL TOR NS SYNC; TIROL TOR NS ASYNC; TIROL TOR MS SYNC; IROL TOR MS ASYNC; VDE-AR-N 4105:2018-11; VDE-AR-N 4105:2018-11; VDE-AR-N 4105:2018-11; VDE-AR-N 4110:2018-11; CEI 0-21:2019; G99/1/3 LV:2018; G99/1/3 HV:2018; G98/1/2:2018; C10-11 2019 LV-IP; C10-11 2019 LV-ASS; C10-11:2019 HV-IP; C10-11:2019 HV-ASS; NA/EEA- CH 2014; NA/EEA-NE7 - CH 2020; NA/EEA-NE7 - CH 2020; EN 50549-1:2019 LV; EN 50549-2:2019 HV; EN 50438:2013 (DK); VDE 0126-1-1:2013 (FR); AB AS 4777.2:2020; C AS 4777.2:2020; NZS 4777.2:2020; NRS 097-2-1: 2017; EN 50438:2013; E 8001/8101; VDE 0124-100:2013; TR3 Rev23:2013; AS/NZS 4777.2:2015; G59/3/3:2015 LV; G59/3/3:2015 MV; G83/2:2012; C10-11:2012 LV; C10-11:2012 MV; C10-11:2019 LV-IP; C10-11:2019 HV-IP; As well as an OPEN SETUP


    Specifications

    AttributeValue
    Monitoring ApplicationFrequency, Voltage
    Electrical Phase3
    Mounting TypeDIN Rail
    SeriesRE
    Operating Temperature Range-15 to +65°C
    Width107mm
    Maximum Operating Temperature+65°C
    Length62mm
    Dimensions107 x 62 x 91mm
    Terminal TypeScrew
    Minimum Operating Temperature-15°C
    Height91mm
    Special FeaturesMains and system protection, Multinational, 64 memory locations, Functionally safe due to internal redundant design, Menu-driven; Integrated test function easily selectable Measuring voltage up to 3 x 400/230V AC, Adheres to 15+ country specific certified standards