Pico Technology ADC-20 & TERM Voltage Data Logger, USB 2.0, 8 Channel
- RS Stock No.:
- 536-8828
- Distrelec Article No.:
- 304-11-392
- Mfr. Part No.:
- ADC-20 & TERM
- Manufacturer:
- Pico Technology
Subtotal (1 unit)*
TWD14,428.00
(exc. GST)
TWD15,149.40
(inc. GST)
FREE delivery for orders over NT$1,300.00
In Stock
- Plus 8 unit(s) shipping from November 09, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | TWD14,428.00 |
*price indicative
- RS Stock No.:
- 536-8828
- Distrelec Article No.:
- 304-11-392
- Mfr. Part No.:
- ADC-20 & TERM
- Manufacturer:
- Pico Technology
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Pico Technology | |
| Product Type | Data Logger | |
| Model Number | ADC-20 & TERM | |
| Measurement Parameters | Voltage | |
| Number of Channels | 8 | |
| Interface Type | USB 2.0 | |
| Data Logger Type | Voltage | |
| Power Source | USB | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 45°C | |
| Width | 184mm | |
| Hazardous Area Certification | No | |
| Height | 36mm | |
| Length | 135mm | |
| Standards/Approvals | No | |
| Resolution | 20 bit | |
| Minimum Measurement | -2500 mV | |
| Maximum Measurement | 2500 mV | |
| Alarm | Yes | |
| Select all | ||
|---|---|---|
Brand Pico Technology | ||
Product Type Data Logger | ||
Model Number ADC-20 & TERM | ||
Measurement Parameters Voltage | ||
Number of Channels 8 | ||
Interface Type USB 2.0 | ||
Data Logger Type Voltage | ||
Power Source USB | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 45°C | ||
Width 184mm | ||
Hazardous Area Certification No | ||
Height 36mm | ||
Length 135mm | ||
Standards/Approvals No | ||
Resolution 20 bit | ||
Minimum Measurement -2500 mV | ||
Maximum Measurement 2500 mV | ||
Alarm Yes | ||
RoHS Status: Exempt
- COO (Country of Origin):
- GB
Pico Technology Data Logger, 8 Channels, USB Power Source - ADC-20 & TERM
This data logger records voltage across multiple channels for monitoring and analysis in controlled environments. It operates from a USB power source and connects via a USB 2.0 interface, making it suited to desktop and portable measurement workflows. The instrument functions within a defined ambient temperature range and provides an audible/visual alert capability for out-of-limit conditions.
Features and Benefits:
• 20 bit resolution delivers finer voltage detail and improved measurement discrimination
• ±2500mV input range supports both positive and negative voltages without scaling
• 8 channel acquisition enables simultaneous multi-point voltage monitoring
• Alarm-enabled design provides immediate notification of threshold breaches
• USB 2.0 Interface offers straightforward data transfer to host systems
• ±2500mV input range supports both positive and negative voltages without scaling
• 8 channel acquisition enables simultaneous multi-point voltage monitoring
• Alarm-enabled design provides immediate notification of threshold breaches
• USB 2.0 Interface offers straightforward data transfer to host systems
Applications
• Suitable for laboratory voltage trend analysis and data capture
• Ideal for multi-sensor electrical test benches in R&D
• Used with portable rigs for field voltage surveys
• Can be used for product validation where multi-channel logging is required
• Useful in educational settings for demonstrating precision voltage measurement
• Ideal for multi-sensor electrical test benches in R&D
• Used with portable rigs for field voltage surveys
• Can be used for product validation where multi-channel logging is required
• Useful in educational settings for demonstrating precision voltage measurement
What temperature conditions must be maintained during operation?
The device should be operated within a 0°C to 45°C ambient range to ensure specified performance.
How is power supplied during measurement sessions?
It draws power directly from a USB connection rather than an internal battery.
What is the maximum measurable voltage on each input?
Each channel accepts voltages up to 2500mV and down to -2500mV providing symmetric input capability.
Which Interface is used to retrieve logged data?
Data is transferred via a USB 2.0 connection to a host computer.
How many simultaneous channels can be recorded?
The unit captures eight channels concurrently for parallel voltage monitoring.
Related links
- Pico Technology ADC-24 & TERM Voltage Data Logger USB 2.0, 8 Channel
- Pico Technology PicoLog 1216 Voltage Data Logger 16 Channel
- Pico Technology PicoLog 1012 Voltage Data Logger 12 Channel
- Pico Technology PicoLog CM3 Current & Voltage Data Logger USB, 3 Channel
- Pico Technology USB TC-08 Temperature Data Logger 8 Channel
- RS PRO PRO-USB-3 Voltage Data Logger, USB
- Extech DL160 Current & Voltage Data Logger 2 Channel
- Lascar EL-USB-3 Voltage Data Logger, USB