Signal Conditioners | RS
Recently searched

    Signal Conditioners

    Signal conditioners are electronic devices used to modify and optimize electrical signals in various measurement and control systems. They are typically employed in situations where the electrical signals from sensors, transducers, or other sources need to be adjusted or conditioned to meet specific requirements.

    How do Signal Conditioners Work?

    The primary purpose of a signal conditioner is to ensure that the signals are suitable for further processing, transmission, or conversion by other devices or systems. Signal conditioners can perform a variety of functions depending on the specific application.

    What are the types of Signal Conditioning?

    Signal conditioners can be classified into several types based on their specific functions and the signals they process. Here are some common types of signal conditioners: Amplifiers: Amplifiers are signal conditioners used to amplify weak input signals. They increase the signal strength to a level suitable for further processing or transmission. Filters: Signal conditioners that incorporate filters are used to remove unwanted noise or interference from the input signals. Different types of filters, such as low-pass, high-pass, band-pass, or notch filters, are used based on the specific frequency ranges to be filtered. Linearizers: Linearizers are signal conditioners that compensate for nonlinearities in the input signal. They apply mathematical algorithms or lookup tables to linearize the output and provide a more linear response over the measurement range. Isolation Amplifiers: These signal conditioners provide electrical isolation between the input and output sides of a system. They protect sensitive measurement equipment from electrical noise, voltage spikes, and ground loops, ensuring accurate and reliable measurements. Converters: Signal conditioners known as converters are used to convert signals from one form to another. For example, analogue-to-digital converters (ADCs) convert analogue signals into digital form, while digital-to-analogue converters (DACs) convert digital signals into analogue form.

    Where are Signal Conditioners Used?

    Signal conditioners are widely used in industrial automation, process control, data acquisition systems, scientific research, and various other fields where accurate and reliable signal processing is essential. They play a crucial role in optimizing signal quality, reducing noise, and improving the overall performance of measurement and control systems.

    700 Products showing for Signal Conditioners

    Phoenix Contact
    Repeater power supply
    Current
    -
    Current
    0 → 20 mA, 4 → 20mA
    0 → 24 mA, 4 → 24mA
    9.6 → 30V dc
    -
    DIN Rail Mount
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MINI MCR
    WAGO
    Isolation Amplifier
    Current, Voltage
    -
    Current, Voltage
    0 → 10 V, 0 → 20mA
    0 → 10 V, 0 → 20mA
    24V dc
    ATEX, IECEx
    DIN Rail Mount
    -25°C
    -25 → +70°C
    +70°C
    -
    -
    857
    Phoenix Contact
    Isolation Amplifier
    Current
    -
    Current
    -50 → 200°C
    -
    19.2 → 30V dc
    ATEX
    DIN Rail
    -20°C
    -20 → +65°C
    +65°C
    -
    -
    3RS7002
    Turck
    Frequency Transducer
    Frequency
    -
    Relay
    3-Wire Input - 12 V dc, NAMUR Input - 8.2 V dc
    = 30 VDC or = 250 VAC
    10 → 30V dc
    Ex, SIL, UL
    -
    -
    -
    -
    -
    -
    IM(X)12
    JM CONCEPT
    AC Voltage Converter
    AC Voltage
    -
    Current, Voltage
    0 → 1000V
    -
    22 → 240 V dc, 90 → 230V ac
    -
    DIN Rail
    -10°C
    -10 → +60°C
    +60°C
    -
    -
    ULCOS 600
    PR Electronics
    Pulse Isolator
    NAMUR Sensor, Switch
    -
    NPN, Relay
    -
    -
    19.2 → 31.2V dc
    ATEX, IECEx
    -
    -
    -
    -
    -
    -
    9200
    Phoenix Contact
    Fiber Optic Converter
    -
    -
    -
    -
    30, 42 V, 60
    -
    ATEX
    -
    -
    -
    -
    -
    -
    PSI-MOS-RS485W2/FO 850 T
    Weidmüller
    Signal Isolator
    Current, Voltage
    -
    Current, Voltage
    0 → 10 V, 0 → 20mA
    0 → 10 V, 0 → 20mA
    24V dc
    -
    DIN Rail Mount
    0°C
    0 → +55°C
    +55°C
    -
    -
    ACT20X
    Phoenix Contact
    Fibre Optic Converter
    -
    -
    Current, Voltage
    -
    0.46 A, 42 V dc, 60V ac
    18 → 30V dc
    ATEX
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    3RS7005
    Schneider Electric
    -
    -
    -
    -
    0 → 5A
    -
    -
    IECEx
    -
    -
    -
    -
    Yes
    Green Premium
    Harmony Analog
    Phoenix Contact
    Limit Value Switch
    RTD, Thermocouple
    -
    Relay
    0 → 4000 Ω
    250 V ac, 100 mA → 6 A, 240V dc
    24V dc
    ATEX
    DIN Rail Mount
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MINI MCR
    Schneider Electric
    -
    -
    -
    -
    0 → 20mA
    -
    -
    IECEx
    -
    -
    -
    -
    Yes
    Green Premium
    Harmony Analog
    SICK
    NAMUR Isolating Amplifier
    -
    -
    -
    -
    -
    -
    ATEX
    DIN Rail Mount
    -20°C
    -
    +60°C
    -
    -
    EN2
    Phoenix Contact
    Fiber Optic Converter
    -
    -
    -
    -
    30, 42 V, 60
    -
    ATEX
    -
    -
    -
    -
    -
    -
    PSI-MOS-PROFIB/FO 850 T
    Phoenix Contact
    Loop Powered Isolator
    Current
    -
    Current
    0 → 20 mA, 4 → 20mA
    0 → 20 mA, 4 → 20mA
    9.6 → 30V dc
    ATEX
    DIN Rail Mount
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MINI MCR
    RS PRO
    Frequency Converter
    Frequency
    -
    Current, Voltage
    0 → 1 kHz, 0 → 10 kHz, 0 → 100 Hz, 0 → 12 kHz, 0 → 16 kHz, 0 → 2 kHz, 0 → 2.5 kHz, 0 → 20 kHz, 0 → 200 Hz, 0 → 24 kHz, 0 → 250 Hz, 0 → 28.8 kHz, 0 → 3 kHz, 0 → 4 kHz, 0 → 400 Hz, 0 → 5 kHz, 0 → 500 Hz, 0 → 6 kHz, 0 → 750
    0 → 10 V, 0 → 20 mA, 4 → 20mA
    16.8 → 30 V dc, 19.2 → 28.8V ac
    -
    DIN Rail Mount
    -25°C
    -25 → +60°C
    +60°C
    -
    -
    MINI MCR-2-V8-MOD-TCP
    Turck
    Resistor Module
    -
    -
    -
    -
    -
    -
    -
    -
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    -
    Phoenix Contact
    Converter
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    IBS
    Phoenix Contact
    Repeater power supply
    -
    -
    Current, Voltage
    -
    0.46 A, 42 V dc, 60V ac
    24V dc
    ATEX, IECEx
    DIN Rail Mount
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    3RS7005
    Phoenix Contact
    Current Transducer
    Current
    -
    -
    11A
    0 → 20mA
    20 → 30V dc
    -
    Chassis Mount
    -20°C
    -
    +60°C
    -
    -
    MCR-S-1
    Results per page