Sine wave output voltage Selectable output frequency: 50/60Hz Adjustable output voltage High input-output isolation 3000Vrms Remote inhibit Remote control via RS232 Alarm by isolated relay contacts Remote off opto-coupled Railway version EN50155 Fire and smoke: EN45545-2 approved DNV GL maritime type approved product
Attribute
Value
Input Voltage
48V dc
Output Voltage
230V ac
Railway Approved
Yes
Efficiency
0.9
MTBF
130000h
Output Current
6.5A
Length
359.5mm
Width
64.5mm
Depth
160mm
Weight
3.8kg
Minimum Temperature
-25°C
Maximum Temperature
+55°C
Standards Met
2014/30/EU, 2014/35/EU, EN 45545-2, EN 50121-3-2, EN 50155, EN 62368-1
Protection Features
Current Protection, Overload Protection, Polarity Protection, Power Protection