Fluke Networks LinkIQ DUO Cable+Wi-Fi+Network Network Tester Internal Antenna, M12x, M12, M8, RJ45, USB
- RS Stock No.:
- 434-340
- Mfr. Part No.:
- LIQ-DUO-IE-KIT-H6-UK
- Manufacturer:
- Fluke Networks
Subtotal (1 unit)*
TWD218,800.00
(exc. GST)
TWD229,740.00
(inc. GST)
FREE delivery for orders over NT$1,300.00
In Stock
- Plus 7 unit(s) shipping from August 10, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | TWD218,800.00 |
*price indicative
- RS Stock No.:
- 434-340
- Mfr. Part No.:
- LIQ-DUO-IE-KIT-H6-UK
- Manufacturer:
- Fluke Networks
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke Networks | |
| Equipment Type | Network Tester | |
| Product Type | Cable Tracer | |
| LAN Category | Cat6a | |
| Connector Type | Internal Antenna, M12x, M12, M8, RJ45, USB | |
| Model Number | LinkIQ DUO Cable+Wi-Fi+Network | |
| Tone | Yes | |
| Power Source | Battery | |
| Battery Type | Lithium-ion | |
| Battery Life | 8h | |
| Display Type | Capacitive Touch Display | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 45°C | |
| Length | 220mm | |
| Height | 50mm | |
| Standards/Approvals | Ethernet Alliance to IEEE 802.3af/at/bt | |
| Weight | 624g | |
| Width | 115mm | |
| Plug Type | USB Type C | |
| Select all | ||
|---|---|---|
Brand Fluke Networks | ||
Equipment Type Network Tester | ||
Product Type Cable Tracer | ||
LAN Category Cat6a | ||
Connector Type Internal Antenna, M12x, M12, M8, RJ45, USB | ||
Model Number LinkIQ DUO Cable+Wi-Fi+Network | ||
Tone Yes | ||
Power Source Battery | ||
Battery Type Lithium-ion | ||
Battery Life 8h | ||
Display Type Capacitive Touch Display | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 45°C | ||
Length 220mm | ||
Height 50mm | ||
Standards/Approvals Ethernet Alliance to IEEE 802.3af/at/bt | ||
Weight 624g | ||
Width 115mm | ||
Plug Type USB Type C | ||
- COO (Country of Origin):
- US
Fluke Cable Tracer, 220mm Length, 624 g Weight - LIQ-DUO-IE-KIT-H6-UK
This cable tracer is a battery‑powered network tester designed for locating and diagnosing network cabling and wireless connectivity in professional environments. It combines cable tracing with Wi‑Fi and network testing capabilities and includes a capacitive touch display for intuitive operation. The tester supports PoE standards and multiple connector interfaces to accommodate industrial and Ethernet cabling workflows.
Features and Benefits:
• Supports Cat6a testing and verification for high‑performance links
• Detects PoE to IEEE 802.3af/at/bt standards for powered devices
• Internal antenna and multi‑connector support for diverse cabling
• Lithium‑ion battery providing 8‑hour continuous operation
• USB‑C interface for charging and data transfer convenience
• Capacitive touch display enabling quick, direct interaction
• Detects PoE to IEEE 802.3af/at/bt standards for powered devices
• Internal antenna and multi‑connector support for diverse cabling
• Lithium‑ion battery providing 8‑hour continuous operation
• USB‑C interface for charging and data transfer convenience
• Capacitive touch display enabling quick, direct interaction
Applications
• Suitable for commissioning Cat6a installations in data centres
• Ideal for on‑site PoE validation during device deployment
• Used with M12 and M8 field cabling in industrial networks
• Can be used for combined Wi‑Fi and wired link troubleshooting
• Used for RJ45 link verification on structured cabling projects
• Ideal for on‑site PoE validation during device deployment
• Used with M12 and M8 field cabling in industrial networks
• Can be used for combined Wi‑Fi and wired link troubleshooting
• Used for RJ45 link verification on structured cabling projects
How long will it operate between charges?
It runs on a lithium‑ion pack rated for approximately 8 hours of typical use.
Which PoE classes can it evaluate?
It assesses power delivery compliance with IEEE 802.3af, 802.3at and 802.3bt specifications.
What connector types are available for direct testing?
It includes interfaces such as RJ45 and industrial M12 and M8 jack options plus internal antenna support.
What environmental conditions can it handle during field use?
It is specified to operate within a temperature range from 0°C up to a maximum of 45°C.
Related links
- Fluke LinkIQ DUO Cable+Wi-Fi+Network Network Tester M12 Internal Antenna RJ45, USB
- Fluke LinkIQ DUO Cable+Wi-Fi+Network Network Tester RJ45 Internal Antenna
- Fluke LinkIQ DUO Cable+Wi-Fi+Network Network Tester M8 RJ45 Internal Antenna, M12
- Fluke LinkIQ DUO Cable+Wi-Fi+Network Network Tester Internal Antenna USB
- Fluke LinkIQ DUO Cable+Wi-Fi+Network Network Tester USB RJ45
- Fluke LinkIQ DUO Cable+Wi-Fi+Network Network Tester USB M8 M12, M12x
- Fluke LinkIQ DUO Cable+Wi-Fi+Network Network Tester USB 2.5 mm Ferrule Adapter, Internal Antenna
- Fluke LinkIQ DUO Cable+Wi-Fi+Network Network Tester USB RJ45, 2.5 mm Ferrule Adapter
