Schneider Electric Multi9 C60SP Miniature Circuit Breaker, 4-Pole, 10 A, Type B, 440 V AC, 20 kA Breaking Capacity
- RS Stock No.:
- 211-2349
- Mfr. Part No.:
- M9F21410
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
TWD7,311.00
(exc. GST)
TWD7,676.55
(inc. GST)
FREE delivery for orders over NT$1,300.00
In Stock
- Plus 7 unit(s) shipping from January 26, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | TWD7,311.00 |
*price indicative
- RS Stock No.:
- 211-2349
- Mfr. Part No.:
- M9F21410
- Manufacturer:
- Schneider Electric
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 4 | |
| Current Rating | 10 A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 440 V | |
| Breaking Capacity | 20kA | |
| Range | Multi9 | |
| Series | C60SP | |
| IP Rating | IP20, IP40 | |
| Width | 72 mm | |
| Standards/Approvals | GB 14048.2, EN/IEC 60947-2, CSA C22.2 No 235, UL 1077 | |
| Height | 81mm | |
| Depth | 72mm | |
| Tripping Mechanism | Thermal Magnetic | |
| Reset Actuator Type | Toggle Switch | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 4 | ||
Current Rating 10 A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 440 V | ||
Breaking Capacity 20kA | ||
Range Multi9 | ||
Series C60SP | ||
IP Rating IP20, IP40 | ||
Width 72 mm | ||
Standards/Approvals GB 14048.2, EN/IEC 60947-2, CSA C22.2 No 235, UL 1077 | ||
Height 81mm | ||
Depth 72mm | ||
Tripping Mechanism Thermal Magnetic | ||
Reset Actuator Type Toggle Switch | ||
- COO (Country of Origin):
- FR
The Schneider Electric's C60SP Series are multi-standard miniature circuit breakers and supplementary protection as defined by UL 1077. It has function such as tripping and electrical fault indication by the addition of auxiliaries.
Circuit protection against short-circuit currents
Circuit protection against overload currents
Related links
- Schneider Electric Multi 9 C60SP MCB 6A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 40A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 20A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 32A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 25A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 10A Curve B 125V DC, 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 2A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 50A Curve B 15 kA Breaking Capacity