Alpha Wire Ecogen Ecowire Series Brown 0.13 mm² Hook Up Wire, 26 AWG, 7, 1000 ft, Modified Polyphenylene Ether, 6711
- RS Stock No.:
- 741-8001
- Mfr. Part No.:
- 6711 BR001
- Manufacturer:
- Alpha Wire
Bulk discount available
Subtotal (1 reel of 305 metres)*
TWD7,476.00
(exc. GST)
TWD7,849.80
(inc. GST)
FREE delivery for orders over NT$1,300.00
Temporarily out of stock
- Shipping from June 08, 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 - 49 | TWD7,476.00 | TWD24.511 |
| 50 - 249 | TWD7,214.00 | TWD23.652 |
| 250 + | TWD5,937.00 | TWD19.466 |
*price indicative
- RS Stock No.:
- 741-8001
- Mfr. Part No.:
- 6711 BR001
- Manufacturer:
- Alpha Wire
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Alpha Wire | |
| Product Type | Hook Up Wire | |
| Cross Sectional Area | 0.13mm² | |
| Jacket Colour | Brown | |
| American Wire Gauge | 26AWG | |
| Core Strands | 7 | |
| Cable Length | 1000ft | |
| Outside Diameter | 0.038in | |
| Voltage | 600V | |
| Maximum Operating Temperature | 105°C | |
| Conductor Material | Copper | |
| Minimum Operating Temperature | -40°C | |
| Jacket Material | Modified Polyphenylene Ether | |
| Cable Type | Hookup | |
| Standards/Approvals | CE, CSA, UL | |
| Sub Type | EcoWire | |
| Fire Behaviour | Flame Retardant | |
| Series | Ecogen Ecowire | |
| Select all | ||
|---|---|---|
Brand Alpha Wire | ||
Product Type Hook Up Wire | ||
Cross Sectional Area 0.13mm² | ||
Jacket Colour Brown | ||
American Wire Gauge 26AWG | ||
Core Strands 7 | ||
Cable Length 1000ft | ||
Outside Diameter 0.038in | ||
Voltage 600V | ||
Maximum Operating Temperature 105°C | ||
Conductor Material Copper | ||
Minimum Operating Temperature -40°C | ||
Jacket Material Modified Polyphenylene Ether | ||
Cable Type Hookup | ||
Standards/Approvals CE, CSA, UL | ||
Sub Type EcoWire | ||
Fire Behaviour Flame Retardant | ||
Series Ecogen Ecowire | ||
Belden Ecogen Ecowire Series Hook Up Wire, 1000ft Cable Length, Brown Jacket - 6711 BR001
This hook-up wire is a thin-gauge copper conductor intended for internal wiring and control circuits in industrial and electronic equipment. It is supplied on a 1000 ft reel and features a brown insulating sheath designed for applications where a compact, flexible connection is required within assemblies operating across a wide temperature range.
Features & Benefits
• 0.13 mm² conductor area provides Compact current carrying capacity
• 7-strand copper construction improves Flex performance
• 600 Vrms rating allows use in many control and signal circuits
• Modified polyphenylene ether jacket offers chemical stability
• VW-1 flame behaviour reduces risk of vertical flame propagation
• Rated for -40 °C to 105 °C for wide ambient endurance
• 7-strand copper construction improves Flex performance
• 600 Vrms rating allows use in many control and signal circuits
• Modified polyphenylene ether jacket offers chemical stability
• VW-1 flame behaviour reduces risk of vertical flame propagation
• Rated for -40 °C to 105 °C for wide ambient endurance
**Applications**
• Suitable for internal wiring of automation cabinets
• Ideal for control wiring in motor drives and sensors
• Used with power supplies in electronic assemblies
• Can be used for harnessing in mechanical control panels
• Ideal for control wiring in motor drives and sensors
• Used with power supplies in electronic assemblies
• Can be used for harnessing in mechanical control panels
How does the conductor construction affect bending life?
The seven-strand copper make-up reduces stiffness compared with solid conductors and helps withstand repeated flexing in confined routing paths.
What insulation characteristics aid installation near heat sources?
The modified polyphenylene ether sheath maintains insulating properties at elevated temperatures up to 105 °C and resists softening under thermal stress.
Are there approvals relevant to use in regulated equipment?
It meets multiple standards including UL AWM STYLE 11028 and CSA AWM classifications, alongside REACH and RoHS directives.
What does the VW-1 classification indicate about fire performance?
VW-1 denotes a vertical wire flame test performance that limits flame spread along the insulation in fault conditions.
Standards
UL AWM 11028 VW-1, CSA AWM I A/B FT1, RoHS/RoHS2 Compliant, IEC 60332-2 Flame Behavior, REACH Compliant, CE Compliant
Related links
- Alpha Wire Ecogen Ecowire Series Orange 0.13 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6711
- Alpha Wire Ecogen Ecowire Series Purple 0.13 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6711
- Alpha Wire Ecogen Ecowire Series Yellow 0.13 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6711
- Alpha Wire Ecogen Ecowire Series Green 0.13 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6711 GR001
- Alpha Wire Ecogen Ecowire Series Blue 0.13 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6711 BL001
- Alpha Wire Ecogen Ecowire Series Slate 0.13 mm² Hook Up Wire 7 Modified Polyphenylene Ether,
- Alpha Wire Ecogen Ecowire Series Slate 0.13 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6711 RD001
- Alpha Wire Ecogen Ecowire Series Grey 0.13 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6711 SL001
