Alpha Wire Hookup Wire TEFLON Series Orange PTFE Equipment Wire, 18 AWG, 19, 30 m, Polytetrafluoroethylene, 5857 OR005
- RS Stock No.:
- 177-1359
- Mfr. Part No.:
- 5857 OR005
- Manufacturer:
- Alpha Wire
Bulk discount available
Subtotal (1 reel of 30 metres)*
TWD10,096.00
(exc. GST)
TWD10,600.80
(inc. GST)
FREE delivery for orders over NT$1,300.00
In Stock
- 16 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 - 49 | TWD10,096.00 | TWD336.533 |
| 50 + | TWD9,793.00 | TWD326.433 |
*price indicative
- RS Stock No.:
- 177-1359
- Mfr. Part No.:
- 5857 OR005
- Manufacturer:
- Alpha Wire
Specifications
Product overview and Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Alpha Wire | |
| Product Type | PTFE Equipment Wire | |
| Jacket Colour | Orange | |
| American Wire Gauge | 18AWG | |
| Core Strands | 19 | |
| Cable Length | 30m | |
| Voltage | 600V | |
| Outside Diameter | 1.75mm | |
| Maximum Operating Temperature | 200°C | |
| Conductor Material | Silver Plated Copper | |
| Sub Type | Type E | |
| Cable Type | Hookup | |
| Jacket Material | Polytetrafluoroethylene | |
| Standards/Approvals | MIL-W-16878/4, NEMA HP-EXBBB, UL1213, VW-1 | |
| Minimum Operating Temperature | -60°C | |
| Fire Behaviour | Flame Retardant | |
| Series | Hookup Wire TEFLON | |
| Select all | ||
|---|---|---|
Brand Alpha Wire | ||
Product Type PTFE Equipment Wire | ||
Jacket Colour Orange | ||
American Wire Gauge 18AWG | ||
Core Strands 19 | ||
Cable Length 30m | ||
Voltage 600V | ||
Outside Diameter 1.75mm | ||
Maximum Operating Temperature 200°C | ||
Conductor Material Silver Plated Copper | ||
Sub Type Type E | ||
Cable Type Hookup | ||
Jacket Material Polytetrafluoroethylene | ||
Standards/Approvals MIL-W-16878/4, NEMA HP-EXBBB, UL1213, VW-1 | ||
Minimum Operating Temperature -60°C | ||
Fire Behaviour Flame Retardant | ||
Series Hookup Wire TEFLON | ||
RoHS Status: Exempt
Belden Hookup Wire TEFLON Series PTFE Equipment Wire, 0.96mm² Cross Sectional Area, Orange Jacket - 5857 OR005
This PTFE equipment wire is a high-temperature, single-core hookup cable designed for demanding electrical and electronic installations where thermal endurance and Compact conductor size are required. It features a silver-plated copper conductor with PTFE insulation, offering reliable performance in confined assemblies and elevated-temperature environments up to 200°C while maintaining a 600Vrms voltage rating suitable for control, signal and power wiring in industrial systems.
Features & Benefits
• Silver-plated copper conductor reduces contact resistance and oxidation
• PTFE insulation endures continuous operation at 200°C maximum
• VW-1 flame-test rating enhances circuit-board and panel safety
• 0.96mm² cross-sectional area supports moderate current carrying
• 19-strand conductor construction improves flexibility and routing
• PTFE insulation endures continuous operation at 200°C maximum
• VW-1 flame-test rating enhances circuit-board and panel safety
• 0.96mm² cross-sectional area supports moderate current carrying
• 19-strand conductor construction improves flexibility and routing
**Applications**
• Suitable for automation control wiring in high-temperature enclosures
• Ideal for internal wiring in industrial electronic assemblies
• Used for wiring in electrical panels subject to elevated heat
• Can be used for interconnects in mechanical systems with tight bend requirements
• Suitable for military-spec cabling requiring Type E compliance
• Ideal for internal wiring in industrial electronic assemblies
• Used for wiring in electrical panels subject to elevated heat
• Can be used for interconnects in mechanical systems with tight bend requirements
• Suitable for military-spec cabling requiring Type E compliance
What is the conductor construction and how does it affect handling?
The conductor comprises 19 strands of silver-plated copper, which gives the cable greater flexibility for routing through confined spaces while maintaining good conductivity.
Which temperature extremes can this cable withstand during operation?
The cable operates reliably between -60°C and 200°C, allowing use in both cold storage and high-temperature process environments.
How does the product comply with environmental substance regulations?
Materials conform to RoHS and REACH criteria, with no listed SVHCs above 0.1% by mass, and meet China SJ/T 11364-2006 marking requirements.
What electrical characteristics support system design calculations?
Voltage rating is 600Vrms and conductor DCR is approximately 5.6Ω/1000 ft at 20°C, with nominal inductance around 0.03μH/ft.
What physical handling limits should be observed during installation?
Recommended minimum bend radius is 10 times the cable diameter and maximum pull tension is 14.9 lb to avoid conductor or insulation damage.
Standards
MIL-DTL-16878/4 (Type E) (600 V), UL AWM 1213, NEMA HP3
Related links
- Alpha Wire Hookup Wire TEFLON Series Orange PTFE Equipment Wire 19 Polytetrafluoroethylene, 5858 OR005
- Alpha Wire Hookup Wire TEFLON Series Orange PTFE Equipment Wire 7 Polytetrafluoroethylene, 5852 OR005
- Alpha Wire Hookup Wire TEFLON Series Orange PTFE Equipment Wire 7 Polytetrafluoroethylene, 5855/7 OR005
- Alpha Wire Hookup Wire TEFLON Series Purple PTFE Equipment Wire 19 Polytetrafluoroethylene, 5857 VI005
- Alpha Wire Hookup Wire TEFLON Series Grey PTFE Equipment Wire 19 Polytetrafluoroethylene, 5857 SL005
- Alpha Wire Hookup Wire TEFLON Series Yellow PTFE Equipment Wire 19 Polytetrafluoroethylene, 5857 YL005
- Alpha Wire Hookup Wire TEFLON Series Green PTFE Equipment Wire 19 Polytetrafluoroethylene, 5857 GR005
- Alpha Wire Hookup Wire TEFLON Series Orange PTFE Equipment Wire 7 5851 OR005
