StarTech.com NLBL, 500 mm Cat8 Ethernet Cable, Shielded, Blue Screened Low Smoke Zero Halogen Sheath

Subtotal (1 unit)*

TWD567.00

(exc. GST)

TWD595.35

(inc. GST)

Add to Basket
Select or type quantity
In Stock
  • 10 unit(s) ready to ship
  • Plus 5 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +TWD567.00

*price indicative

RS Stock No.:
473-500
Mfr. Part No.:
NLBL-50C-CAT8-PATCH
Manufacturer:
StarTech.com
Find similar products by selecting one or more attributes.
Select all

Brand

StarTech.com

Series

NLBL

Product Type

Ethernet Cable

Cable Length

500mm

LAN Category

Cat8

Sub Type

Patch Cord

Shield Type

Shielded

Screened/Unscreened

Screened

Conductor Type

Solid

Jacket Colour

Blue

Jacket Material

Low Smoke Zero Halogen

Minimum Operating Temperature

0°C

Maximum Operating Temperature

50°C

Standards/Approvals

TIA/EIA T568B, IEEE 802.3ba 40GBASE T

Fire Behaviour

LSZH

Conductor Material

Copper

Outside Diameter

5.6mm

COO (Country of Origin):
CN

StarTech.com NLBL Series Ethernet Cable, 500mm Cable Length, Blue Jacket - NLBL-50C-CAT8-PATCH


This ethernet cable provides a short, screened connection for high-speed network links in indoor environments. It is intended for use where a shielded, low-emission link is required between devices that follow common wiring schemes and high-bandwidth Ethernet standards. The cable combines a solid copper conductor design with a low-smoke, zero-halogen jacket to meet demanding site safety and performance needs.

Features and Benefits:


• 40GBASE-T support for high-throughput network performance
• Screened construction reduces electromagnetic interference
• 26AWG solid conductors ensure stable signal transmission
• LSZH jacket minimises toxic smoke in confined spaces
• Rated to operate up to 50°C for warm equipment rooms

Applications


• Suitable for short cross-connects in data centres
• Ideal for screened links between switches and appliances
• Used for high-bandwidth test setups in electronics labs
• Can be used for automation cabinet internal patching

Which wiring scheme does it support for termination?


It is wired to the T568B standard for consistent pair alignment in structured cabling.

What core count and conductor form does it use?


The cable contains four cores with a solid copper conductor profile to favour point-to-point stability.

How does the outer material affect installation in public buildings?


The low-smoke, zero-halogen jacket reduces harmful emissions during combustion, making it suitable for indoor installations where smoke toxicity is a concern.

What shielding type is provided and why is that important?


The cable is screened to limit external interference and preserve signal integrity in electrically noisy environments.

What is the cable outside diameter and why might that matter?


The outside diameter measures 5.6mm which aids planning for conduit fill and connector compatibility.

Related links

Be the first to know about our latest products and offers

Email address

The personal information you provide to us when signing up to this mailing list will be processed in line with the Privacy Policy