Air Quality Meters

Air quality meters are devices designed to monitor and check the quality of the indoor and outdoor air. These compact, handheld machines are able to measure all essential parameters such as humidity, temperature, air volume, air velocity, CO, CO2, and % of outdoor air calculation.
These devices are ideal for detecting indoor gas leaks and measuring the gas levels such as Volatile Organic Compounds, Formaldehyde, and Freon, Nitrogen Dioxide, Ozone and many more flammable, hazardous or toxic gases.
Some Air Quality Meters store the measurement scores and allow transferring them to the computer for further analysing and reporting.

Types of Air Quality Meters:
- Portable/Handheld Meters – These type of meters are ideal for engineers working on location. They provide accurate measurements and store results for further analysis.
- Desktop/Stationary Meters – Stationery meters are perfect for indoor operation for example in laboratories. They are very accurate in terms of measuring the quality of the air and can be plugged into the main power source so batteries aren’t necessary.

Air Quality meters are necessary devices for every gas engineer and are ideal for proving that gas appliances such as space heaters or kitchen equipment are operating safely.

Where are air quality meters used?
- Facility maintenance
- HVAC systems
- Indoor air quality investigations
- Monitoring clean rooms
- Manufacturing processes
- Pharmaceutical production
- Testing filter seals
- Locating particle contamination sources
- Monitoring particle size distribution

...
Read more Read less

Filters

Viewing 1 - 20 of 68 products
Results per page
Description Price Maximum Temperature Best Temperature Measurement Accuracy Temperature Measurement Resolution Maximum Humidity Measurement Best Humidity Measurement Accuracy Humidity Measurement Resolution Carbon Monoxide Resolution Best Carbon Monoxide Accuracy Carbon Dioxide Resolution Best Carbon Dioxide Accuracy Data Logging Power Source Battery Type Battery Life
RS Stock No. 516-7091
Mfr. Part No.0563 4354
BrandTesto
TWD28,380
Each
units
+150 °C, +400 °C, +1370 °C ±0.5% + 0.4 °C 0.1°C 100%RH - 0.1%RH - - 1ppm - Yes Battery AA 200 h
RS Stock No. 762-1247
Mfr. Part No.FLUKE 985
BrandFluke
TWD220,389
Each
units
- 95 %RH - 95%RH 95 %RH - - - - - Yes Battery, Mains Rechargeable Li-Ion 5 h, 10 h
RS Stock No. 131-347
Mfr. Part No.FLUKE-975
BrandFluke
TWD154,760
Each
units
+50°C ±1.1 °C 0.1°C 90%RH ±2 %RH 1%RH 1ppm ±3ppm 1ppm ±2.75% + 75 ppm Yes Battery AA (Backup), Rechargeable Lithium-Ion (Primary) 11 h
RS Stock No. 131-353
Mfr. Part No.FLUKE-975V
BrandFluke
TWD169,686
Each
units
+50°C ±1.1 °C 0.1°C 90%RH ±2 %RH 1%RH 1ppm ±3ppm 1ppm ±2.75% + 75 ppm Yes Battery AA (Backup), Rechargeable Lithium-Ion (Primary) 11 h
RS Stock No. 106-5304
BrandRS PRO
TWD7,742
Each
units
+50 °C, +122 °F ±1.0 °C, ±1.8 °F 0.1 °C, 0.1 °F 95%RH ±3 % 0.1% - - ±1ppm ±5% - Mains - -
RS Stock No. 176-5574
Mfr. Part No.0563 4404
BrandTesto
TWD15,547
Each
units
+150 (Temperature-NTC) °C, +1370 (Temperature-TC) °C ±0.3 (-25 → +74.9 °C) °C, ±0.4 (+75 → +99.9 °C) °C, ±0.4 (-40 → -25.1 °C) °C, ±0.5 % 0.1°C - - - - - - - Yes Battery AA 12 h
RS Stock No. 176-5575
Mfr. Part No.0563 4405
BrandTesto
TWD27,236
Each
units
+150 (Temperature-NTC) °C, +1370 (Temperature-TC) °C ±0.3 (-25 → +74.9 °C) °C, ±0.4 (+75 → +99.9 °C) °C, ±0.4 (-40 → -25.1 °C) °C, ±0.5 % 0.1°C - - - - - - - Yes Battery AA 12 h
RS Stock No. 176-5605
Mfr. Part No.0632 1272
BrandTesto
TWD11,690
Each
units
- - - - - - 0.1ppm ±3ppm - - - - - -
RS Stock No. 146-4656
BrandRS PRO
TWD93,361
Each
units
+40°C ±3 (+10 → +40 °C) °C - 90%RH ±7 (20 → 90 %RH - Non-Condensing) % - - - - - Yes Battery, Mains Li-ion 4 h
RS Stock No. 176-5585
Mfr. Part No.0635 1032
BrandTesto
TWD8,183
Each
units
+70°C ±0.5 °C 0.1 - - - - - - - - - - -
RS Stock No. 176-5576
Mfr. Part No.0563 4406
BrandTesto
TWD33,080
Each
units
+150 (Temperature-NTC) °C, +1370 (Temperature-TC) °C ±0.3 (-25 → +74.9 °C) °C, ±0.4 (+75 → +99.9 °C) °C, ±0.4 (-40 → -25.1 °C) °C, ±0.5 % 0.1°C - - - - - - - Yes Battery AA 12 h
RS Stock No. 176-5610
Mfr. Part No.0615 1712
BrandTesto
TWD2,532
Each
units
+125°C ±0.2 (-25 → +80 °C) °C, ±0.4 °C - - - - - - - - - - - -
RS Stock No. 176-5612
Mfr. Part No.0635 1570
BrandTesto
TWD17,534
Each
units
+70°C ±0.5 (0 → +70 °C) °C, ±0.8 (-20 → 0 °C) °C 0.1°C 95%RH ±2 (35 → 65 %RH) %RH, ±3 (10 → 35 %RH) %RH, ±3 (65 → 90 %RH) %RH, ±5 %RH 0.1%RH - - - - - - - -
RS Stock No. 176-5624
Mfr. Part No.0554 0960
BrandTesto
TWD5,066
Each
units
- - - - - - - - - - - - - -
RS Stock No. 176-5606
Mfr. Part No.0628 0152
BrandTesto
TWD31,170
Each
units
+50°C ±0.5 °C 0.1°C - - - - - - - - - - -
RS Stock No. 146-9079
BrandRS PRO
TWD28,429
Each
units
+50 °C, +122 °F ±0.5 °C, ±1 °F - 100%RH ±2.5 %RH - - ±5% - - - Battery NiMH -
RS Stock No. 176-5572
Mfr. Part No.0563 4402
BrandTesto
TWD21,002
Each
units
+150 (Temperature-NTC) °C, +1370 (Temperature-TC) °C ±0.3 (-25 → +74.9 °C) °C, ±0.4 (+75 → +99.9 °C) °C, ±0.4 (-40 → -25.1 °C) °C, ±0.5 % 0.1°C - - - - - - - Yes Battery AA 12 h
RS Stock No. 181-0416
Mfr. Part No.KANE101
BrandKane
TWD22,495
Each
units
+60 (Probe)°C ±1 % 0.1°C 95%RH ±5 %RH 0.1%RH 1ppm ±10% 1ppm ±10% - Battery Rechargeable NiMH 6 h
RS Stock No. 176-5581
Mfr. Part No.0563 4410
BrandTesto
TWD54,509
Each
units
+150 (Temperature-NTC) °C, +1370 (Temperature-TC) °C ±0.3 (-25 → +74.9 °C) °C, ±0.4 (+75 → +99.9 °C) °C, ±0.4 (-40 → -25.1 °C) °C, ±0.5 % 0.1°C - - - - - - - Yes Battery AA 12 h
RS Stock No. 176-5611
Mfr. Part No.0615 5505
BrandTesto
TWD1,675
Each
units
+125°C ±1 (-20 → +85 °C) °C - - - - - - - - - - - -