Better World
Schneider Electric LC1D Series Contactor, 48 V ac Coil, 3-Pole, 150 A, 3NO, 1 kV ac, 690 V dc
- RS Stock No.:
- 744-7248
- Mfr. Part No.:
- LC1D1506E7
- Manufacturer:
- Schneider Electric
Temporarily out of stock - back order for despatch 10/05/2024, delivery within 6 working days
Price (VAT excluded) Each
Was TWD26,448.00
You pay
TWD22,481.00
(exc. GST)
TWD23,605.05
(inc. GST)
units | Per unit |
1 + | TWD22,481.00 |
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 744-7248
- Mfr. Part No.:
- LC1D1506E7
- Manufacturer:
- Schneider Electric
Legislation and Compliance
Product Details
3 pole Contactors, AC Controlled, over 18kW power rating
TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards.
Features and Benefits.
Utilisation category AC3
415Vac switching voltage
3 pole NO
415Vac switching voltage
3 pole NO
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?
- Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
- AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.
- AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.
What accessories are available?
- Auxiliary contact blocks with serrated wiping action.
- Front mount dust tight auxiliary contact blocks.
- Pneumatic time delay blocks.
- Transient voltage surge suppressors.
- Interface modules and electronic timers.
- Mechanical latching blocks.
Is the TeSys D range a double break pole type contactor?
- Yes, the Tesys D range uses linear translation movement that provides double breaking of the poles.
Specifications
Attribute | Value |
---|---|
Coil Voltage | 48 V ac |
Number of Poles | 3 |
Contact Voltage Rating | 1 kV ac, 690 V dc |
Contact Current Rating | 150 A |
Range | TeSys D |
Series | LC1D |
Normal State Configuration | 3NO |
Auxiliary Contact Configuration | 1NO + 1NC |
Number Of Auxiliary Contacts | 2 |
Terminal Type | Lug Ring Terminal / Bus Bar |
Width | 120mm |
Length | 158mm |
Depth | 136mm |
Better World Product | Yes |
Better World Verification | Green Premium |