- RS Stock No.:
- 914-5424
- Mfr. Part No.:
- Fluke 376
- Manufacturer:
- Fluke
- RS Stock No.:
- 914-5424
- Mfr. Part No.:
- Fluke 376
- Manufacturer:
- Fluke
Product overview and Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
- COO (Country of Origin):
- CN
Product Details
FLUKE 376 True RMS AC/DC Clamp Meter, 18in iFlex Current Probe, Low Pass Filter - 370 FC Series
Stay in the loop about the status of your electrical system with the 376 AC/DC clamp meter with iFlex from FLUKE. You can use it to measure AC or DC voltage up to 1000V and current up to 1000A. If you add the 18in iFlex current probe, you can boost the current measurement range up to 2500A. Noisy electrical environments are no problem, thanks to an integrated low pass filter and state-of-the-art signal processing that ensure stable readings in all conditions.
Features & Benefits
• Logging capability lets you spot intermittent faults while performing other tasks
• Operating temperature range of -10°C to +50°C means you can use it in harsh environments
• TPAK magnetic hanging strap makes it convenient for taking readings in the field
• Use it with the Fluke Connect app to create and share reports remotely
• Large backlit display
• Operating temperature range of -10°C to +50°C means you can use it in harsh environments
• TPAK magnetic hanging strap makes it convenient for taking readings in the field
• Use it with the Fluke Connect app to create and share reports remotely
• Large backlit display
Applications
• Plant inspections
• Electricians
• HVAC maintenance
• Electricians
• HVAC maintenance
What are true-RMS measurements?
RMS stands for root-mean-square. In short, true-RMS meters use mathematical equations to measure both nonsinusoidal and pure sinusoidal waves. This gives a much more accurate reading of AC voltage or current signals than conventional digital measuring tools.
Specifications
Attribute | Value |
---|---|
Absolute Maximum AC Current Measurement | 1000A ac |
Absolute Maximum DC Current Measurement | 1000A dc |
Absolute Maximum AC Voltage Measurement | 1000V ac |
Absolute Maximum DC Voltage Measurement | 1000V dc |
Absolute Maximum Resistance Measurement | 60kΩ |
Model Number | 376 |
AC Current Measurement Resolution | 0.1A |
DC Current Measurement Resolution | 0.1A |
Best DC Current Accuracy | 2 % |
Clamp Meter Type | AC/DC Clamp Meter |
Best AC Current Accuracy | 2.5 % |
Best AC Voltage Accuracy | 1.5 % |
Functions Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance |
Jaw Capacity Busbars | 34mm |
True RMS | Yes |
Best DC Voltage Accuracy | 1 % |
DC Current Measurement Range | 999.9 A |
Resistance Measurement Resolution | 100mΩ |
Length | 83mm |
Width | 43mm |
Power Source | Battery |
AC Voltage Measurement Resolution | 0.1V |
Height | 246mm |
Dimensions | 83 x 43 x 246mm |
Minimum Operating Temperature | -10°C |
Safety Category Voltage | 600 V, 1000V |
Safety Category Level | CAT III, CAT IV |
Weight | 388g |
AC Voltage Measurement Range | 1000 V |
AC Current Measurement Range | 999.9 A |
Best Resistance Measurement Accuracy | 1 % |
Safety Category | CAT III 1000 V, CAT IV 600V |
Battery Type | AA |
Maximum Operating Temperature | +50°C |
DC Voltage Measurement Resolution | 0.1V |
Display Type | Backlight |