Fluke 376 Clamp Meter, Max Current 999.9A ac, 999.9A dc CAT III 1000 V, CAT IV 600 V

  • RS Stock No. 914-5424
  • Mfr. Part No. Fluke 376
  • Manufacturer Fluke
Product overview and Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): CN
Product Details

Fluke 376 True RMS AC/DC Clampmeter with iFlex

The Fluke 376 clampmeter offers improved performance for a wide range of current measurement situations. With True RMS voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes. The new 18 in (458 mm) iFlex flexible current probe is included. It expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward-sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 clampmeter.

Features & Benefits

Large backlit display
1000 A ac and dc current measurement with fixed jaws
2500 A ac current measurement with iFlex flexible current probe
1000 V ac (True RMS) and dc voltage measurement
500 mV dc measurement range to interface with other accessories
Frequency, capacitance, resistance and continuity measurement
Display HOLD, Min, max, average and inrush recording
Low pass filter for stable readings in noisy environments
CAT IV 600 V, CAT III 1000 V safety rating

Measurement Range Resolution Accuracy

Measurement Range Resolution Accuracy
AC Current via Jaw 1000 A 0.1 A ±(2% + 5 d)
AC Current via iFlex 2500 A 0.1 A ±(3% + 5 d)
DC Current 1000 A 0.1 A ±(2% + 5 d)
AC Voltage 1000 V 0.1 V ±(1.5% + 5 d)
DC Voltage 1000 V 0.1 mV ±(1% + 5 d)
Resistance 60000 Ω 0.1 Ω ±(1% + 5 d)
Frequency 500 Hz 0.1 Hz ±(0.5% + 5 d)
Capacitance 1000 μF 1 μF ±(1% + 4 d)
Fixed jaw capacity 32mm diameter (750 MCM or 2-500 MCM)

• 1000 A ac and dc current measurement
• 2500 A ac current measurement with iFlex flexible current probe
• 1000 V ac and dc voltage measurement
• True-rms voltage and current for accurate measurements on non-linear signals
• Frequency measurement to 500 Hz with body jaw and iFlex
• Resistance measurement to 60 kΩ with continuity detection
• Min, max, average, and inrush recording to capture variations automatically
• 500 mV dc measurement range to interface with other accessories
• 1000 μF capacitance measurement
• Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
• Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
• iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
• TPAK magnetic hanging strap (included)
• Integrated VFD low pass filter for accurate motor drive measurements
• Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
• CAT IV 600 V, CAT III 1000 V safety rating

Supplied with

18in iFlex current probe, test leads, soft carry case, 2 x AA alkaline batteries and instructions

Fluke True-RMS Clamp Meter

The Fluke True-RMS clamp meter measures current up to 1000A (AC/DC) with fix jaw and iFlex™ flexible current probe expands the measurement range to 2500 A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access. The Integrated low pass filter and state of the art signal processing allow for use in noisy electrical environments while providing stable readings. This meter contains an 18in iFlex current probe, TL75 test leads, soft carry case, 2xAA alkaline batteries, TPAK magnetic hanging strap, and instructions.

Features and Benefits

Voltage measurement is 1000V AC/DC Frequency measurement up to 500Hz with body jaw and iFlex Resistance measurement up to 60kohm with continuity detection Minimum, maximum, average and inrush recording to capture variations automatically 500mVDC measurement range to interface with other accessories Capacitance measurement is 1000μF Capture intermittent faults while performing other tasks using the logging capabilities Create and share reports from the field via email or converse in real-time with ShareLive video calls Integrated VFD low pass filter for accurate motor drive measurements Proprietary inrush measurement technology to filter out the noise and capture motor starting current exactly as the circuit protection sees it Display HOLD Operating temperature ranges between -10°C and 50°C

Applications

Petrochemical industry Oil and gas Food and beverages Pharmaceuticals

Certifications

CE cCSAus TUV CAT IV 600V, CAT III 1000V safety rating

Specifications
Attribute Value
Absolute Maximum AC Current Measurement 999.9A ac
Absolute Maximum DC Current Measurement 999.9A dc
Absolute Maximum AC Voltage Measurement 1000V ac
Absolute Maximum DC Voltage Measurement 1000V dc
Absolute Maximum Resistance Measurement 60kΩ
Model Number 376
AC Current Measurement Resolution 0.1A
DC Current Measurement Resolution 0.1A
Best DC Current Accuracy 2 %
Clamp Meter Type AC/DC Clamp Meter
Best AC Current Accuracy 2.5 %
Best AC Voltage Accuracy 1.5 %
Best DC Voltage Accuracy 1 %
Dimensions 83 x 43 x 246mm
Resistance Measurement Resolution 100mΩ
Length 83mm
Width 43mm
Power Source Battery
Safety Category CAT III 1000 V, CAT IV 600 V
Battery Type AA
Safety Category Voltage 600 V, 1000 V
Safety Category Level CAT III, CAT IV
Weight 388g
Jaw Capacity Busbars 34mm
AC Voltage Measurement Resolution 0.1V
Minimum Operating Temperature 10°C
Height 246mm
DC Voltage Measurement Resolution 0.1V
Functions Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance
True RMS Yes
Display Type Backlight
Maximum Operating Temperature 50°C
Best Resistance Measurement Accuracy 1 %
1 Within 3 working day(s) (local stock)
63 Within 6 working day(s) (Global stock)
Price (VAT excluded) Each
TWD 21,629.00
(exc. GST)
TWD 22,710.00
(inc. GST)
units
Per unit
1 +
TWD21,629.00