- RS Stock No.:
- 415-216
- Mfr. Part No.:
- TIS50
- Manufacturer:
- Eaton
Temporarily out of stock - back order for despatch 21/05/2024, delivery within 6 working days
Added
Price (VAT excluded) Each
TWD768.00
(exc. GST)
TWD806.40
(inc. GST)
Units | Per unit |
1 + | TWD768.00 |
- RS Stock No.:
- 415-216
- Mfr. Part No.:
- TIS50
- Manufacturer:
- Eaton
Product overview and Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
Product Details
Red Spot™ Range, Type T HBC
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A
Features and Benefits
Breaking capacity 80kA ac 40kAdc
Rated up to 550Vac/ 250Vdc (Type A1) & 660Vac/ 460Vdc (Type A2)
General purpose (gG) and dual motor rated (gM) types
Low power dissipation
660Vac rated (A1 types 415Vac)
ASTA 20 certified
Rated up to 550Vac/ 250Vdc (Type A1) & 660Vac/ 460Vdc (Type A2)
General purpose (gG) and dual motor rated (gM) types
Low power dissipation
660Vac rated (A1 types 415Vac)
ASTA 20 certified
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A.
Eaton British Standard Fuse, A3, 50A TIS50
This low-voltage industrial fuse from Eaton's Red Spot range is used to provide protection to electrical circuits and improve safety for both operators and equipment.
Designed to be a sacrificial device, this component breaks the current flow to a circuit in the event of a short circuit or overload fault that could otherwise cause damage. The fuse can be used for both gG (general purpose) and gM (dual motor) protection and is a common feature of electrical wiring and switchgear systems.
Designed to be a sacrificial device, this component breaks the current flow to a circuit in the event of a short circuit or overload fault that could otherwise cause damage. The fuse can be used for both gG (general purpose) and gM (dual motor) protection and is a common feature of electrical wiring and switchgear systems.
Features & Benefits
T speed to accommodate harmless inrush currents without opening the fuse
8.7mm wide offset bolted brackets for easy attachment to fuse holders
Current rating of 50A for use in heavy-duty applications
High breaking capacity of 80kA to withstand high temperatures
Weight of 58.2g, so won't add strain to equipment
8.7mm wide offset bolted brackets for easy attachment to fuse holders
Current rating of 50A for use in heavy-duty applications
High breaking capacity of 80kA to withstand high temperatures
Weight of 58.2g, so won't add strain to equipment
How do I replace a blown fuse?
First, identify where the outage has occurred, then unplug the equipment and turn off the power. It's important to know the specifications of the blown fuse so its equivalent can be used as a replacement. When you're sure of this, detach the fuse from its holder and insert the new one.
Note
Eaton formerly known as Bussmann
Specifications
Attribute | Value |
---|---|
Current Rating | 50A |
Fuse Size | A3 |
Voltage Rating | 660V ac |
Fuse Standard | BS 88-2, IEC 269-2 |
Fixing Centres | 73mm |
Application Category | gG, gM |
Tag Width | 8.7mm |
Fuse Speed | T |
High Rupture Capacity | Yes |
Overall Length | 85.5mm |
Tag Type | Bolted |
Body Diameter | 22.2mm |
Tag Orientation | Offset |
Body Height | 56.4mm |
Fuse Dimensions | 22 x 86mm |
Series | Bussmann |