- RS Stock No.:
- 172-0525
- Mfr. Part No.:
- SG444420
- Manufacturer:
- Celduc
3 In stock for delivery within 6 working days
Added
Price (VAT excluded) Each
TWD10,542.00
(exc. GST)
TWD11,069.10
(inc. GST)
Units | Per unit |
1 + | TWD10,542.00 |
- RS Stock No.:
- 172-0525
- Mfr. Part No.:
- SG444420
- Manufacturer:
- Celduc
Product overview and Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
- COO (Country of Origin):
- FR
Product Details
Phase Angle and Frequency Burst Regulators
SG5 relays with proportional control have an analogue input isolated from the mains allowing a proportional variation of the operating duty cycle at this input through the generation of frequency bursts.
Applications: heating regulation.- Ve = 0 V → t/T = 0%
- Ve = 5 V → t/T = 50%
- Ve = 10 V → t/T = 100%.
The SG4 models have an analogue input isolated from the mains allowing a proportional variation at this input of the switching instant on the sine wave.
Applications: motor speed variation, dimmable lighting.
Specific documentation available on request.
Applications: heating regulation.- Ve = 0 V → t/T = 0%
- Ve = 5 V → t/T = 50%
- Ve = 10 V → t/T = 100%.
The SG4 models have an analogue input isolated from the mains allowing a proportional variation at this input of the switching instant on the sine wave.
Applications: motor speed variation, dimmable lighting.
Specific documentation available on request.
Proportional and Power
Note
Temperature can affect current rating; please consult the data sheet for potential derating.
Specifications
Attribute | Value |
---|---|
Maximum Load Current | 40 A |
Mounting Type | Panel Mount |
Maximum Load Voltage | 265 V rms |
Minimum Load Voltage | 115 V ac |
Minimum Control Voltage | 0 V |
Maximum Control Voltage | 5 V dc |
Switching Type | Phase Angle |
Control Voltage Range | 1 → 5 V dc |
Minimum Load Current | 10 mA |
Range | SG4 |
Number of Poles | 1 |
Terminal Type | Screw |
Output Device | Triac |
Relay Type | Single Phase angle controller |
Series | SG4 |
Maximum Turn On Time | 10ms |
Load Voltage Range | 115 → 265V ac |
Dimensions | 100 x 73.5 x 39.5mm |
Depth | 73.5mm |
Operating Temperature Range | -40 → +85°C |
Height | 39.5mm |
Length | 100mm |
Standards Met | CE, EAC |
Minimum Operating Temperature | -40°C |
Maximum Operating Temperature | +85°C |